menu
{ "item_title" : "Boiler Water Treatment Principles and Practice", "item_author" : [" Colin Frayne "], "item_description" : "Table of Contents: About the Author - Saturated steam temperatures at various boiler pressures - Boiler Energy and Power Units - Typical gross heating values of common fuels (based on approximately 80% fuel to steam efficiency) - Typical energy consumption and output ratings for a fire tube boiler - Steam tables suitable for pressure deaerators - Calculating Blowdown - Coefficients of thermal conductivity for some heat-exchanger metals and boiler deposits - Types of water or steam commonly employed in most HW heating and steam generating plants - Commonly occurring minerals in natural MU water sources - Specific waterside / steamside problems affecting MPHW and HPHW boiler plants - Salt concentration indicators - Summary of waterside / steamside problems affecting LPHW and LP steam heating boiler plants - FW contamination from MU water - FW contamination from returned condensate - Problems associated with the final FW blend - Deposition of boiler section waterside surfaces by alkaline earth metal salts, other inorganic salts and organics - Silica and silicate crystalline scales and deposits affecting boiler section waterside surfaces - Iron oxide and other boiler section corrosion debris deposits - Boiler section corrosion problems involving oxygen, concentration cells and low pH - Stress and high temperature related corrosion - Steam purity, quality and other operational problems - Specification for grades of high-quality water suitable for higher pressure WT boilers - Practical considerations for a RW ion-exchange softener - Types of Internal Treatment Program - Carbonate Cycle Requirement Calculations - Phosphate-Cycle Requirement Calculations - A Guide to Tannin Residuals in BW - Carbonate-Cycle Program. BW Carbonate Reserve Requirements by Pressure and Sulfate Concentration - Carbonate-Cycle Coagulation and Precipitation Program. Recommended BW Control Limits for Non-Highly-Rated FT Boilers Employing Hard or Partially Softened FW - Phosphate-Cycle Coagulation and Precipitation Program. Recommended BW Control Limits for Non-Highly-Rated FT Boilers Employing Hard, Partially Softened, or Fully Softened FW - Phosphate-Cycle Coagulation and Precipitation Program. Recommended BW Control Limits for Non-Highly-Rated WT Boilers Employing Hard, Partially Softened, or Fully Softened FW - Chelant demand (ppm product) per 1ppm substrate EDTA Chelant or All-Polymer/All-Organic Program. Recommended BW Control Limits for Fired WT Boilers Employing Demineralized or Similar Quality FW - Oxygen Solubility at Atmospheric Pressure - Properties of Oxygen Scavengers - Carbon Dioxide Evolution from FW Alkalinity - Amine Requirement to Reach a Stable Condensate pH - Amine Basicity Dissociation Constants - Neutralizing Amine Summary Notes - Some DR values for CO2, NH3 and neutralizing amines at various pressures - Calculating Alkalinity Feed-Rate Requirements -ASME Consensus table 1: Suggested water chemistry limits. Industrial watertube, high duty, primary fuel fired, drum typeMakeup water percentage: Up to 100% of feedwater. Conditions: Includes superheater, turbine drives or process restriction on steam purity] -ASME Consensus table 2: Suggested chemistry limits. Industrial watertube, high duty, primary fuel fired, drum type] -ASME Consensus table 3: Suggested chemistry limits. Industrial firetube, high duty, primary fuel fired] -ASME Consensus table 4: Suggested water chemistry limits. Industrial coil type, watertube, high duty, primary fuel fired rapid steam generators] -ASME Consensus table 5: Suggested water chemistry limits. Marine propulsion, watertube, oil fired drum type] -ASME Consensus table 6: Suggested water chemistry limits. Electrode, high voltage, forced circulation jet type] - Notes", "item_img_path" : "https://covers4.booksamillion.com/covers/bam/0/82/060/173/082060173X_b.jpg", "price_data" : { "retail_price" : "125.00", "online_price" : "125.00", "our_price" : "125.00", "club_price" : "125.00", "savings_pct" : "0", "savings_amt" : "0.00", "club_savings_pct" : "0", "club_savings_amt" : "0.00", "discount_pct" : "10", "store_price" : "" } }
Boiler Water Treatment Principles and Practice|Colin Frayne

Boiler Water Treatment Principles and Practice : Charts and Notes for Field Use

local_shippingShip to Me
In Stock.
FREE Shipping for Club Members help

Overview

Table of Contents: About the Author - Saturated steam temperatures at various boiler pressures - Boiler Energy and Power Units - Typical gross heating values of common fuels (based on approximately 80% fuel to steam efficiency) - Typical energy consumption and output ratings for a fire tube boiler - Steam tables suitable for pressure deaerators - Calculating Blowdown - Coefficients of thermal conductivity for some heat-exchanger metals and boiler deposits - Types of water or steam commonly employed in most HW heating and steam generating plants - Commonly occurring minerals in natural MU water sources - Specific waterside / steamside problems affecting MPHW and HPHW boiler plants - Salt concentration indicators - Summary of waterside / steamside problems affecting LPHW and LP steam heating boiler plants - FW contamination from MU water - FW contamination from returned condensate - Problems associated with the final FW blend - Deposition of boiler section waterside surfaces by alkaline earth metal salts, other inorganic salts and organics - Silica and silicate crystalline scales and deposits affecting boiler section waterside surfaces - Iron oxide and other boiler section corrosion debris deposits - Boiler section corrosion problems involving oxygen, concentration cells and low pH - Stress and high temperature related corrosion - Steam purity, quality and other operational problems - Specification for grades of high-quality water suitable for higher pressure WT boilers - Practical considerations for a RW ion-exchange softener - Types of Internal Treatment Program - Carbonate Cycle Requirement Calculations - Phosphate-Cycle Requirement Calculations - A Guide to Tannin Residuals in BW - Carbonate-Cycle Program. BW Carbonate Reserve Requirements by Pressure and Sulfate Concentration - Carbonate-Cycle Coagulation and Precipitation Program. Recommended BW Control Limits for Non-Highly-Rated FT Boilers Employing Hard or Partially Softened FW - Phosphate-Cycle Coagulation and Precipitation Program. Recommended BW Control Limits for Non-Highly-Rated FT Boilers Employing Hard, Partially Softened, or Fully Softened FW - Phosphate-Cycle Coagulation and Precipitation Program. Recommended BW Control Limits for Non-Highly-Rated WT Boilers Employing Hard, Partially Softened, or Fully Softened FW - Chelant demand (ppm product) per 1ppm substrate EDTA Chelant or All-Polymer/All-Organic Program. Recommended BW Control Limits for Fired WT Boilers Employing Demineralized or Similar Quality FW - Oxygen Solubility at Atmospheric Pressure - Properties of Oxygen Scavengers - Carbon Dioxide Evolution from FW Alkalinity - Amine Requirement to Reach a Stable Condensate pH - Amine Basicity Dissociation Constants - Neutralizing Amine Summary Notes - Some DR values for CO2, NH3 and neutralizing amines at various pressures - Calculating Alkalinity Feed-Rate Requirements - ASME Consensus table 1: Suggested water chemistry limits. Industrial watertube, high duty, primary fuel fired, drum typeMakeup water percentage: Up to 100% of feedwater. Conditions: Includes superheater, turbine drives or process restriction on steam purity] - ASME Consensus table 2: Suggested chemistry limits. Industrial watertube, high duty, primary fuel fired, drum type] - ASME Consensus table 3: Suggested chemistry limits. Industrial firetube, high duty, primary fuel fired] - ASME Consensus table 4: Suggested water chemistry limits. Industrial coil type, watertube, high duty, primary fuel fired rapid steam generators] - ASME Consensus table 5: Suggested water chemistry limits. Marine propulsion, watertube, oil fired drum type] - ASME Consensus table 6: Suggested water chemistry limits. Electrode, high voltage, forced circulation jet type] - Notes

This item is Non-Returnable

Details

  • ISBN-13: 9780820601731
  • ISBN-10: 082060173X
  • Publisher: Chemical Publishing Company
  • Publish Date: July 2013
  • Dimensions: 8.5 x 5.5 x 0.14 inches
  • Shipping Weight: 0.19 pounds
  • Page Count: 66

Related Categories

You May Also Like...

    1

BAM Customer Reviews